Eaton Cutler-Hammer - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 9 Amp, Nonreversible Open Enclosure NEMA Motor Starter - 1-1/2 hp at 1 Phase


Item #: 04578589
Brand: Eaton Cutler-Hammer
Model #: AN16AN0BC
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 9
NEMA Size 00
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 1 Phase 1-1/2
Overall Height (mm) 98.60
Overall Height (Decimal Inch) 3.8800
Overall Width (mm) 44-1/2
Overall Width (Decimal Inch) 1-3/4
Overall Depth (mm) 88.60
Overall Depth (Decimal Inch) 3.4900
Standards Met CSA Certified; UL Listed

$953.06

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 440 Coil VAC at 50 Hz, 480 Coil VAC at 60 Hz, 18 Amp, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 3 at 200 VAC, 3 at 230 VAC, 5 at 460 VAC, 5 at 575 VAC, 1 Enclosure Rating


Item #: 56823636
Brand: Square D
Model #: 8536SBG2V06C
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 18
NEMA Size 0
Coil Voltage 440 VAC @ 50 Hz; 480 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 3 @ 200 VAC; 3 @ 230 VAC; 5 @ 460 VAC; 5 @ 575 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,096.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 9 Amp, Nonreversible Enclosed Enclosure NEMA Motor Starter - 1 Phase hp: 1 at 230 VAC, 1/3 at 115 VAC, 1 Enclosure Rating


Item #: 56823313
Brand: Square D
Model #: 8536SAG11V03
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 9
NEMA Size 00
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 1 Phase 1 @ 230 VAC; 1/3 @ 115 VAC
Standards Met CSA; RoHS Compliant; UL Listed

$457.93

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 45 Amp, NEMA Size 2, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 200 VAC, 15 at 230 VAC, 25 at 460 VAC, 25 at 575 VAC, 1 Enclosure Rating


Item #: 69651453
Brand: Square D
Model #: 8536SDG1V03
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 45
NEMA Size 2
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 10 @ 200 VAC; 15 @ 230 VAC; 25 @ 460 VAC; 25 @ 575 VAC
Standards Met CSA; RoHS Compliant; UL Listed

$1,191.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Suppressor Module - For Use with LC1D80-D95, LP1D80 and TeSys D


Item #: 56829765
Brand: Schneider Electric
Model #: LA4DE3U
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Suppressor Module
For Use With LC1D80-D95; LP1D80; TeSys D

$39.83

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 to 38 Amp, Contactor Coil - For Use with LC1D09-D38, LC1DT20-DT40 and TeSys D


Item #: 69663870
Brand: Schneider Electric
Model #: LXD1LE7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D09-D38; LC1DT20-DT40; TeSys D
Compatible Contactor Amperage 9-38

$54.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 27 Amp, NEMA Size 1, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC


Item #: 69651529
Brand: Square D
Model #: 8536SCO3V03
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CSA; RoHS Compliant; UL Listed

$624.40

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 40 to 65 Amp, Contactor Coil - For Use with LC1D40A-D65A, LC1DT60A, LC1DT80A and TeSys D


Item #: 69663813
Brand: Schneider Electric
Model #: LXD3T7
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1D40A-D65A; LC1DT60A; LC1DT80A; TeSys D
Compatible Contactor Amperage 40-65

$65.10

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 440 Coil VAC at 50 Hz, 480 Coil VAC at 60 Hz, 27 Amp, NEMA Size 1, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC, 12 Enclosure Rating


Item #: 56823891
Brand: Square D
Model #: 8536SCA3V06A
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 12 refers to enclosures constructed (without knockouts) for indoor use. They provide a degree of protection from falling dirt, circulating dust, lint, fibers, flyings, water dripping and light splashing.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 440 VAC @ 50 Hz; 480 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 12
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,655.26

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 45 Amp, NEMA Size 2, Nonreversible Enclosed Enclosure NEMA Motor Starter - 1 Phase hp: 3 at 115 VAC, 7-1/2 at 230 VAC, 1 Enclosure Rating


Item #: 56814676
Brand: Square D
Model #: 8536SDG6V03
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 45
NEMA Size 2
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 1 Phase 3 @ 115 VAC; 7 1/2 @ 230 VAC
Standards Met CSA; RoHS Compliant; UL Listed

$1,179.05

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, Contactor Mounting Bracket - For Use with Lighting Contactors


Item #: 54422209
Brand: Square D
Model #: 9999RLX
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Mounting Bracket
For Use With Lighting Contactors
Compatible Contactor Amperage 30

$50.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 18 Amp, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 3 at 200 VAC, 3 at 230 VAC, 5 at 460 VAC, 5 at 575 VAC, 1 Enclosure Rating


Item #: 56823610
Brand: Square D
Model #: 536SBG2V02H309S
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 18
NEMA Size 0
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 3 @ 200 VAC; 3 @ 230 VAC; 5 @ 460 VAC; 5 @ 575 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$924.46

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, Contactor Coil - For Use with SIZE 2+60A


Item #: 54421516
Brand: Square D
Model #: 3106340038
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With SIZE 2+60A
Compatible Contactor Amperage 60

$198.88

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 440 Coil VAC at 50 Hz, 480 Coil VAC at 60 Hz, 270 Amp, NEMA Size 5, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 100 at 230 VAC, 200 at 460 VAC, 200 at 575 VAC, 75 at 200 VAC


Item #: 56824527
Brand: Square D
Model #: 8536SGO1V06S
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 270
NEMA Size 5
Coil Voltage 440 VAC @ 50 Hz; 480 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 100 @ 230 VAC; 200 @ 460 VAC; 200 @ 575 VAC; 75 @ 200 VAC
Standards Met CSA; NEMA; UL Listed

$13,847.62

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Mounting Plate - For Use with TeSys D GV


Item #: 69664167
Brand: Schneider Electric
Model #: LAD31
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Mounting Plate
For Use With TeSys D GV

$5.52

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 27 Amp, NEMA Size 1, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC, 1 Enclosure Rating


Item #: 56823958
Brand: Square D
Model #: 536SCG3V02CSX11
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,679.53

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 440 Coil VAC at 50 Hz, 480 Coil VAC at 60 Hz, 45 Amp, NEMA Size 2, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 200 VAC, 15 at 230 VAC, 25 at 460 VAC, 25 at 575 VAC, 3R Enclosure Rating


Item #: 56814627
Brand: Square D
Model #: 8536SDH1V06
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 3R refers to enclosures constructed for either indoor or outdoor use. They provide a degree of protection from falling dirt, rain, sleet, snow and external formation of ice on the enclosure.
Product Specifications
Amperage 45
NEMA Size 2
Coil Voltage 440 VAC @ 50 Hz; 480 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 3R
Horsepower at 3 Phase 10 @ 200 VAC; 15 @ 230 VAC; 25 @ 460 VAC; 25 @ 575 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,808.30

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 90 Amp, NEMA Size 3, Reversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 25 at 200 VAC, 30 at 230 VAC, 50 at 460 VAC, 50 at 575 VAC


Item #: 49787914
Brand: Square D
Model #: 8736SEO2V02S
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Reversing starters are designed with three individual lines that connect to and run voltage through a motor. Each line alternates in a sequence as they reach their voltage peak. They are used to reverse the rotation of a motor.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 90
NEMA Size 3
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Open
Action Reversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 25 @ 200 VAC; 30 @ 230 VAC; 50 @ 460 VAC; 50 @ 575 VAC
Standards Met CSA; UL Listed

$4,751.05

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - Contactor Enclosure - For Use with 9070EO2/EO3/EO4/EO15/EO16/EO18/EO19/T75/T100/T150/T200/T250/T300/T350/T500 Transformer


Item #: 69651073
Brand: Square D
Model #: 9991LG1
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Enclosure
For Use With 9070EO2/EO3/EO4/EO15/EO16/EO18/EO19/T75/T100/T150/T200/T250/T300/T350/T500 Transformer

$184.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 9 Amp, Nonreversible Enclosed Enclosure NEMA Motor Starter - 1 hp at 1 Phase, 1 Enclosure Rating


Item #: 54541651
Brand: Square D
Model #: 8536SAG12V02ES
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 9
NEMA Size 00
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 1 Phase 1
Overall Height (mm) 254
Overall Height (Decimal Inch) 10
Overall Width (mm) 152
Overall Width (Decimal Inch) 6
Overall Depth (mm) 141
Overall Depth (Decimal Inch) 5.5600
Standards Met CE IEC 947-4-1; CSA File No. LR60905 Class 3211 04; UL Listed File No. E78351 CCN NLDX